Even the most reliable boilers can occasionally encounter issues. When your Alpha boiler displays an error code, it can cause significant stress, especially when you're left without heating or hot water. Understanding these fault codes is the first step you carry out towards a quick and effective solution.
This guide explains the most common Alpha boiler error codes, explaining what they mean and what steps you can take to resolve them. While some issues can be fixed with a simple reset or adjustment, many require the expertise of a qualified Gas Safe registered engineer.
- What We Discuss Here
- » Common Alpha Boiler Error Codes
- - How to Fix an E01 Error Code
- - How to Fix an E10 Fault Code
- - How to Fix an E20 Fault Code
- - How to Fix an E96 Fault Code
- » Common Alpha Boiler Warning Lights
- - Solid Red Light (Error 47 – Burner Failed to Ignite)
- - Red + Yellow Lights Flashing Together
- - Flashing Red Light Only
- - No Hot Water
- - Low Boiler Pressure (Error E10)
- - Water Not Hot Enough
- » List of Alpha Boiler Error Codes
- » When to Call an Engineer?
- » Your Next Steps for Boiler Repairs
- » Frequently Asked Questions
Common Alpha Boiler Error Codes

Certain error codes appear more frequently than others. Whether you're dealing with an Alpha boiler E10 fault code or your E-Tec model isn't heating up, knowing what to look for can save you time and worry. Let's start with the most common faults you might encounter.
For London homeowners and landlords, a malfunctioning boiler can disrupt daily life and tenant satisfaction. If you find yourself facing a persistent fault code, our team of certified engineers at serviceteam is ready to provide prompt and reliable boiler repairs.
How to Fix an E01 Error Code
The Alpha boiler E01 fault code indicates a problem with the ignition system. This means the boiler attempted to light the burner to heat the water but failed to detect a flame.
Before calling an engineer, the first thing you should do is check your gas supply. You need to make sure that other gas appliances in your home are functioning properly. If the gas supply is fine with no cases, the exact issue is likely more complex and could be caused by one of the following:
- A gap in the ignition or flame sensor electrode
- Damaged pressure tubes
- A faulty ignition generator or lead
- Incorrect gas valve settings
Fixing these problems requires removing the boiler casing and handling gas components, which only a Gas Safe registered engineer is qualified to do. Do not attempt to fix this yourself.
How to Fix an E10 Fault Code
An Alpha boiler E10 fault code indicates that the water pressure in your heating system is too low (low boiler pressure). The boiler's pressure will likely have dropped below the recommended level (usually 0.6 bar), causing it to shut down as a safety precaution.
You can often resolve this issue yourself by repressurising the system. Your boiler's user manual will provide specific instructions on how to do this using the filling loop. After adding water, the pressure should rise to the correct level (typically between 1 and 1.5 bar).
However, a frequent loss of pressure often indicates an underlying problem, such as a boiler leak in the heating system. If you find yourself repeatedly needing to top up the pressure, it's wise to have an engineer inspect your system for leaks.
How to Fix an E20 Fault Code
The Alpha boiler fault code E20 shows that the boiler is unable to detect a flame. In response, the system shuts down to prevent any safety risks. This is a fault that requires professional attention. An engineer will need to investigate the cause, which could be related to the gas supply, the flame sensor, or the ignition unit.
How to Fix an E96 Fault Code
When the Alpha boiler E96 fault appears, it can point to two different problems. The first possibility is a faulty fan, which is crucial for expelling harmful gases from the boiler. The second is a blockage in the flue.
Both scenarios require a certified engineer to diagnose and repair the issue, as it involves accessing the internal components of the boiler.
Our blog ‘How to Find a Reliable and Trustworthy Engineer’ will guide you through the key steps to making the right choice.
Common Alpha Boiler Warning Lights
When the lights on your Alpha boiler start flashing, it's the boiler's way of telling you something's wrong. Below is a straightforward guide to what those lights mean and what you can do before calling a professional.
Solid Red Light (Error 47 – Burner Failed to Ignite)
If the "A" indicator shows a solid red light, your boiler hasn't managed to light the flame – meaning no heat or hot water.
Quick Fix:
Turn the front selector switch to the reset position and leave it for 25–30 seconds. In many cases, this will restart the flame.
If it doesn't work:
There may be a blockage in the gas valve or burner. At this stage, it's best to call a Gas Safe engineer in London to clean and check the system properly.
Red + Yellow Lights Flashing Together
If both the red "A" and yellow "B" lights flash, the burner is failing to ignite for a different reason.
Quick Fix:
Try resetting by turning the control dial back to position 3.
If that fails:
This could point to issues with the burner fan, gas valve, or even the ignition connections. A qualified engineer should inspect for blocked or faulty components.
Flashing Red Light Only
A flashing red "A" light (with the yellow light off) usually means an overheating problem.
This might be linked to:
- A pump fault
- Blocked or restricted pipework
- Flue sensor problems
- An airlock in the heat exchanger
Action:
This isn't something you should tackle on your own. Call a qualified boiler engineer to diagnose and repair your boiler safely.
No Hot Water
If you're not getting any hot water, check:
- Is the power light on? If not, there's no electrical supply.
- Does the fan run, but ignition fails? That points to an ignition or pilot fault.
- Does it fire up and then cut out? Likely a gas valve issue.
Sometimes a stuck diverter valve is to blame, which might free up. More often, the diverter valve or flow sensor will need replacing.
Low Boiler Pressure (Error E10)
If your gauge indicates low pressure or displays error code E10, it means your heating system has lost pressure – typically due to a leak somewhere in the system.
Action:
Top up the boiler pressure as per your manual, but arrange for a professional to find and repair the leak quickly to avoid long-term damage.
Water Not Hot Enough
If your water is only lukewarm, two common causes are:
- A faulty temperature sensor (thermistor)
- Limescale build-up (a common issue in hard-water areas like London)
Action:
An engineer can test the sensor and descale or replace parts as needed.
List of Alpha Boiler Error Codes
Here is a comprehensive table of all Alpha boiler error codes to help you identify the specific issue with your boiler.
| Error Code | Fault Description |
|---|---|
| 1 | Failure of the ignition system |
| 2 | Boiler overheat lockout |
| 3 | Thermostat temperature too high |
| 4 | Fault within the gas valve electrical connection |
| 5 | Heating flow sensor fault |
| 6 | Faulty sensor in the domestic hot water system |
| 8 | Maximum number of resets exceeded |
| 10 | Low primary system pressure |
| 12 | Fault in the cylinder sensor |
| 15 | An error within the internal wiring |
| 16 | Faulty fan |
| 20 | A fault with the sensing of a flame |
| 24 | Fault with the control panel button |
| 25 | Overheat lockout |
| 27 | Insufficient primary flow |
| 29 | Fault with the flue sensor |
| 31 | Communication lost with the external control |
| 37 | Voltage supply is too low |
| 38 | Rectification due to loss of flame |
| 43 | Rectification due to loss of flame |
| 44 | Lockout due to a safety issue |
| 46 | Intervention by an external sensor |
| 47 | Burner output has been reduced |
| 96 | Faulty fan or a blocked flue |
When to Call an Engineer?
While some resets are safe to try, repeated faults or flashing lights usually mean an underlying issue. For your safety:
- Always call a Gas Safe registered engineer in London for gas-related problems.
- Don't ignore repeated low-pressure or overheating warnings – these can cause bigger breakdowns later.
Your Next Steps for Boiler Repairs
Regular maintenance, such as an annual boiler service, is the best way to prevent unexpected breakdowns and keep your boiler running efficiently. However, there comes a time when the cost of repeated repairs outweighs the price of a new boiler.
If you're in London and need a fast, reliable repair or are considering a boiler replacement, contact serviceteam today. Our gas heating engineers are experts in all Alpha boiler models and can provide a fixed-price quote to restore your heating and hot water.
Checkout our ‘boiler error codes’ bog section to understand more about error codes and solutions.
Need a new boiler?
You can get a boiler quote in 60 seconds.
Frequently Asked Questions
What is the E10 Error on the Alpha Boiler?The E10 error code indicates that the water pressure in the system is too low. The boiler requires a specific pressure level to operate safely, and this error indicates that it has dropped below the required threshold. This can be caused by a leak, recently bleeding radiators, or simply the system needing to be repressurised.
What is the Error Code E1 on the Alpha Boiler?The Alpha E1 error code usually points to a problem with the boiler's thermistor or temperature sensor. This could indicate that the boiler is overheating or that the sensor itself is malfunctioning. An engineer will need to check the sensor's connections or replace it if necessary.
How Do I Fix My E27 Alpha Fault Code?The Alpha E27 fault code indicates a flame detection fault. This can be due to issues with the ignition, flame sensor, or gas supply. You can check that your gas supply is active, but resolving the issue will likely require a certified engineer to clean the flame sensor, inspect the ignition electrodes, or diagnose a more complex problem.
Why is My Alpha Boiler Flashing A and B?When your Alpha boiler flashes "A" and "B," it usually indicates a specific operational mode or fault. The exact meaning depends on your boiler model. It's best to consult your user manual for an accurate interpretation and guidance on what to do next.
Why is the Red Light Flashing on My Alpha Boiler?This typically signals a fault or lockout condition. This safety measure can be triggered by several issues, including overheating, low water pressure, or an ignition failure. An error code will often accompany the flashing light to help identify the specific problem.
Why Does My Alpha Boiler Keep Turning Off?If your Alpha boiler keeps turning off, it could be due to several reasons, such as low water pressure, a blocked condensate pipe (especially in cold weather), overheating, or a problem with the thermostat. The boiler is likely "locking out" as a safety precaution. Checking the pressure gauge and looking for an error code are the first steps in diagnosing the issue.